Liquid-cooled container lithium battery energy storage specifications

Liquid-cooled container lithium battery energy storage specifications

The ECO-B20FT4472LS liquid-cooled battery container offers 4.472MWh capacity with advanced cooling, high protection, and optimized efficiency. Designed for grid-side, renewable, and C&I applications, it ensures safe, reliable, and scalable energy storage.

6 FAQs about [Liquid-cooled container lithium battery energy storage specifications]

What is the containerized lithium battery energy storage system?

The containerized lithium battery energy storage system is based on a 40-foot standard container, and the lithium iron phosphate battery system, PCS, BMS, EMS, air conditioning system, fire protection system, power distribution system, etc. are gathered in a special box to achieve high integration.

What is ENERC liquid cooled energy storage battery containerized energy storage system?

EnerC liquid-cooled energy storage battery containerized energy storage system is an integrated high energy density system, which is in consisting of battery rack system, battery management system (BMS), fire suppression system (FSS), thermal management system (TMS) and auxiliary distribution system.

How many battery cells are in a ENERC liquid cooled container?

The battery system is composed of 10 battery racks in parallel. Each battery rack contains 8 battery modules by series connection, each battery module is composed of 52 battery cells in series connection also, so each rack contains 416 battery cells. Totally, EnerC liquid-cooled container’s configuration is 10P416S.

What is a liquid cooling system?

The integrated frequency conversion liquid cooling system helps limit the temperature difference among cells within 3 ℃, which also contributes to its long service life. It has a nominal capacity of 372.7 kWh with a floor space of just 1.69 square meters. The system is suitable for inverters with operating voltages ranging from 600 to 1500 volts.

What is ENERC liquid cooled container?

Totally, EnerC liquid-cooled container’s configuration is 10P416S. Total 52 pieces lithium iron cells (280Ah/3.2V) in series connection are used for every battery module. For safety protection, an internal high speed DC fuse is included, and removable MSD switch can cut off the high voltage connection during transportation process.

How many lithium iron cells are used in a battery module?

Total 52 pieces lithium iron cells (280Ah/3.2V) in series connection are used for every battery module. For safety protection, an internal high speed DC fuse is included, and removable MSD switch can cut off the high voltage connection during transportation process. *liquid cooling battery module