Distance requirements between energy storage container and factory building

Distance requirements between energy storage container and factory building

In Section 15.5 of NFPA 855, we learn that individual ESS units shall be separated from each other by a minimum of three feet unless smaller separation distances are documented to be adequate and approved by the authority having jurisdiction (AHJ) based on large-scale fire testing.

6 FAQs about [Distance requirements between energy storage container and factory building]

What are the safety requirements for electrical energy storage systems?

Electrical energy storage (EES) systems - Part 5-3. Safety requirements for electrochemical based EES systems considering initially non-anticipated modifications, partial replacement, changing application, relocation and loading reused battery.

What does NFPA 855 mean for energy storage systems?

Specifically, we’re focused on spacing requirements and limitations for energy storage systems (ESS). NFPA 855 sets the rules in residential settings for each energy storage unit—how many kWh you can have per unit and the spacing requirements between those units.

How much energy can a ESS unit store?

Individual ESS units shall have a maximum stored energy of 20 kWh per NFPA Section 15.7. NFPA 855 clearly tells us each unit can be up to 20 kWh, but how much overall storage can you put in your installation? That depends on where you put it and is defined in Section 15.7.1 of NFPA 855.

What are the energy storage operational safety guidelines?

In addition to NYSERDA’s BESS Guidebook, ESA issued the U.S. Energy Storage Operational Safety Guidelines in December 2019 to provide the BESS industry with a guide to current codes and standards applicable to BESS and provide additional guidelines to plan for and mitigate potential operational hazards.

How far apart should storage units be positioned?

Therefore, if you install multiple storage units, you have to space them three feet apart unless the manufacturer has already done large-scale fire testing and can prove closer spacing will not cause fire to propagate between adjacent units.

Can energy storage be co-located with energy generation?

Co-locating energy storage with energy generation is becoming increasingly common. Energy storage could be co-located with solar panels, wind turbines, hydroelectric generators, hydrogen production facilities or storage or different battery technologies.