Energy storage liquid cooling system integrated management measures

Energy storage liquid cooling system integrated management measures

Aiming at the problem of insufficient energy saving potential of the existing energy storage liquid cooled air conditioning system, this paper integrates vapor compression refrigeration technology, vapor pump heat pipe technology and heat pump technology into the field of energy storage temperature control, and carries out an experimental study on the 5 MWh energy storage battery container with reference to the typical battery charging and discharging model.

6 FAQs about [Energy storage liquid cooling system integrated management measures]

What is a data center cooling and energy storage system?

In this study, a system for data center cooling and energy storage is proposed. The system combines the liquid cooling technology with the Carnot battery energy storage technology. The liquid cooling module with the multi-mode condenser can utilize the natural cold source.

Can data center cooling and energy storage meet current electricity pricing policies?

Continuous power and cooling requirements of data center make it difficult for conventional energy management systems to meet the current electricity pricing policies. In this study, a system for data center cooling and energy storage is proposed. The system combines the liquid cooling technology with the Carnot battery energy storage technology.

What is the COP of a liquid cooling module?

The liquid cooling module with the multi-mode condenser can utilize the natural cold source. The Carnot battery module can recover liquid cooling module waste heat and realize efficient energy storage. The main conclusions are as follows: When the outdoor temperature is −10∼30 °C, the COP of the liquid cooling module is 45∼25.

Can a multi-mode liquid-cooling system integrate with a Carnot battery energy storage module?

In this study, the feasibility of the multi-mode liquid-cooling system integrated with the Carnot battery energy storage module is analyzed. Three typical cities are selected as application sites, and the analysis is carried out based on annual performance, payback period, and sensitivity.

What is the SD of a novel cooling system in Guangzhou?

In Guangzhou, the SD of the novel, rack-level, and room-level cooling systems are 14.1 kW h, 188.1 kW h, and 119.7 kW h, respectively. The energy consumption fluctuation of the novel system equipped with the energy storage module is low, which benefits the power grid stability. (28) SD = ∑ i = 1 n (y i − y ‾) 2 n − 1

What type of cooling system is used in a data center?

The novel system belongs to the chip-level system. Currently, conventional rack-level and room-level cooling systems are widely adopted in the data center. In the previous research, the author conducted the cooling system retrofit project for a data center with a total load of 160 kW.